Bently Nevada

Sort By:  
The Commtest vb7 and Scout100-Ex Two-Channel Vibration Analyzers are suitable for every level of vibration analyst - From novice to expert . These instruments offer the power and convenience of dual-channel measurement and dual-plane balancing. Their balancing functions enable quick diagnosis and correction of dynamic unbalance. The SCOUT100-Ex and vb7 instruments combine accuracy, intuitive operation, ease of use, and outstanding storage capacity to ensure a premium return on investment. The SCOUT100-Ex is certified for an ATEX Zone 2 hazardous rating, whereas the vb7 is rated for CSA Class 1, Division 2.
$2,240.00
The vb8 instrument is a portable four-channel vibration data collector, analyzer and balancer. You can use this device for on-route and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb8 is certified for Class 1 Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb8 provides recordings with up to 12,800 lines of resolution and up to 80 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording. The vb8 has plenty of storage and long battery life. This device is backed by five years of warranty. The vb8 is one of Bently Nevada hardware monitoring assets that work with System 1* and Ascent* Level 2 software.
$4,270.00
SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer and balancer. You can use this device for onroute data collection, machine-side analysis and diagnosis, and on-site dynamic balance correction. SCOUT100-Ex is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. This instrument is light but rugged and includes a neck strap with an integrated Sensor Keeper. The integrated Sensor Keeper retains your sensor while you walk orclimb to reach other machines.
$3,260.00
The SCOUT140EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports four-channel vibration data collection, analysis,and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.The SCOUT140EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
$3,550.00
SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer and balancer. You can use this device for onroute data collection, machine-side analysis and diagnosis, and on-site dynamic balance correction. SCOUT100-Ex is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. This instrument is light but rugged and includes a neck strap with an integrated Sensor Keeper. The integrated Sensor Keeper retains your sensor while you walk orclimb to reach other machines.
$2,180.00
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
$5,390.00
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
$5,690.00
Bently Nevada Commtest VB7 Vibration Analysis System - USED (Bently Nevada Commtest VB7)
The Commtest VB7 Dual Channel Vibration Analyzer offers the power and convenience of dual-channel measurement and dual-plane balancing. Its balancing functions enable quick diagnosis and correction of dynamic unbalance, the most common form of unbalance. The VB7 Vibration Analyzer's combination of accuracy, intuitive operation, ease of use, and outstanding storage capacity ensures the instrument delivers a premium return on investment. The Commtest VB7 includes the powerful, award-winning Ascent software.

SPECS :

Sensor input
2 channels

Compatible sensor types
Accelerometer, velocity, displacement, current

AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output swing (± 80 g)

DC coupled ranges
0 V to 20 V, -10 V to 10 V, -20 V to 0 V

Analog to digital conversion
24-bit ADC

Sensor excitation current
0 mA or 2.2 mA (configurable), 24 V maximum

Laser sensor range
10 cm to 2 m nominal

Power supply to sensor
5 V, 50 mA

TTL pulse rating
3.5 V (4 mA) min, 28 V (5 mA) max, off-state 0.8 V

Speed range
10 to 300 000 RPM (0.2 to 5 kHz)

Output to drive strobe
Up to 140 Hz (8400 CPM)

Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz up to 16 kHz to 20 kHz

Long time waveform Fmax
25 Hz to 40 kHz

Dimensions (W x L x H)
9.9” x 5.8”  x 2.4” (252 x 148 x 60) mm

Weight
2.7 lb. (1.2 kg)

Operating temperature
14°F to 122°F (-10°C to 50°C)

Includes :

COMM-CBCC0027 | BNC adapter cable
COMM-CBVB0032 | Carry Case
GENE-12V-3.0A | Power supply
GENE-PC-10A/125V | Power Cord
GENE-CAR-ADAPT01 | Car Charger for cigarette lighter
GENE-USB | USB Cable, Type A to Type B, 6'
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-BATT0206 | Battery Pack (installed)
COMM-VB7-COIL-CBL01 | Accelometer Coiled Cable
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB7-QSG01 | Quick Start Guide
COMM-VB*-CD01 | Implementation Success Training CD
WILC-780A-IS-NR | Accelerometer 5% tolerance and a broad 3dB frequency response from 0.4 Hz to 14 kHz
COMM-VB7-MBS01 | Magnetic Base with Adjustable Stand
COMM-L766 | Tachometer Extension Cable, 5 meter
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-LASA0315 | Laser tachometer
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
DELL-LATITUDE-D620 | 2GB RAM, RS232 Interface, Windows XP Pro Laptop Computer
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-MAGM0064 | Accelometer Magnetic Base, Male
The Commtest vb7 and Scout100-Ex Two-Channel Vibration Analyzers are suitable for every level of vibration analyst - From novice to expert . These instruments offer the power and convenience of dual-channel measurement and dual-plane balancing. Their balancing functions enable quick diagnosis and correction of dynamic unbalance. The SCOUT100-Ex and vb7 instruments combine accuracy, intuitive operation, ease of use, and outstanding storage capacity to ensure a premium return on investment. The SCOUT100-Ex is certified for an ATEX Zone 2 hazardous rating, whereas the vb7 is rated for CSA Class 1, Division 2.
$2,240.00
Bently Nevada Commtest VB8 Four Channel Vibration Analysis System - USED (Commtest VB8)
The vb8 instrument is a portable four-channel vibration data collector, analyzer and balancer. You can use this device for on-route and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb8 is certified for Class 1 Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb8 provides recordings with up to 12,800 lines of resolution and up to 80 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording. The vb8 has plenty of storage and long battery life. This device is backed by five years of warranty. The vb8 is one of Bently Nevada hardware monitoring assets that work with System 1* and Ascent* Level 2 software.

The Bently Nevada VB Series Condition Monitors are built to robust professional standards, making them the first choice for numerous leading companies around the world. Featuring powerful, condition monitoring software, this tiered instrument range varies in features and price, enabling you to select the model with the set of features you require. The VB Series models are rated for CSA Class 1, Division 2.

The vb7 instrument is a portable dual channel vibration data collector, analyzer and balancer. You can use this device for onroute and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb7 is certified for Class 1Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb7 provides recordings with up to 6,400 lines of resolution and up to 40 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording.

The vb8 instrument is a portable four-channel vibration data collector, analyzer and balancer. You can use this device for on route and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb8 is certified for Class 1Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb8 provides recordings with up to 12,800 lines of resolution and up to 80 kHz Fmax. Our patented adaptive settling algorithm and 6 Pack recording system offer quick, one-step data recording.

Features

Dual or four channel models
Measurement range (1,000 g, 25,000 mm/s, 2,500mm)
Tachometer input
40 kHz Fmax (vb7) or 80 kHz Fmax (vb8)
6,400 or 12,800 lines FFT resolution
Two-place balancing
≥ 95 dB dynamic range
Spectrum and waveform recordings
1GB memory and virtually unlimited spectra storage
Integration with System 1 Condition Monitoring and Diagnostic software

INCLUDED :

Bently Nevada Commtest Transducer Cable
Bently Nevada Commtest Laser Tachometer Cable
Bently Nevada Commtest Triple BNC Cable
Bently Nevada Commtest Accelerometer Straight Cable (Green)
Bently Nevada Commtest Accelerometer Straight Cable (Red)
Frontier Wireless Sensor Kit
Bently Nevada vbX Battery Pack
Bently Nevada Commtest Carry Bag
Bently Nevada Commtest Dustcover
Bently Nevada Commtest Keyphasor Tachometer Cable
Bently Nevada Commtest 2-Channel Balancing Kit
Bently Nevada Commtest 4-Channel Balancing Kit
Bently Nevada Commtest Laser Tachometer
Bently Nevada Commtest Laser Tachometer and Block
Bently Nevada Commtest Laser Tachometer Magnetic Base
Bently Nevada Commtest Accelerometer Magnetic Base (Female)
Bently Nevada Commtest Accelerometer Magnetic Base (Male)
Bently Nevada Commtest Safety Rings
Bently Nevada Commtest 780A-IS Accelerometer
Bently Nevada Commtest 787A-IS Accelerometer
Bently Nevada Commtest Power Supply
Bently Nevada S1 Remote Training for Portables
Bently Nevada Neck Strap


The vb8 instrument is a portable four-channel vibration data collector, analyzer and balancer. You can use this device for on-route and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb8 is certified for Class 1 Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb8 provides recordings with up to 12,800 lines of resolution and up to 80 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording. The vb8 has plenty of storage and long battery life. This device is backed by five years of warranty. The vb8 is one of Bently Nevada hardware monitoring assets that work with System 1* and Ascent* Level 2 software.
$4,270.00
Bently Nevada SCOUT100-Ex Vibration Analyzer , Data Collector, Balancer - NEW (SCOUT100-Ex)
The SCOUT100-EX Vibration Data Collector, Analyzer andBalancer is a portable hardware monitoring device thatsupports dual-channel vibration data collection, analysis, andbalancing. Use the device to collect data from sensors on aroute, for machine-side analysis and diagnosis, and on-sitedynamic balance correction.

The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.

The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.

The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:

- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years

Specifications

Sensors

Sensor input
Two Channels Simultaneous sampling

Compatible sensor types
Accelerometer, velocity,displacement, current

AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)

DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap

Connectors 
Safety feature: Break-free inline connector

Analog to digital conversion
24-bit ADC

Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer

Sensor detection
Warns if short circuit or not connected

Waveform Display

Number of samples
1024, 2048, 4096, 8192, 16,384

Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs

Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered

Long time waveform
25 Hz to 40 kHz

Fmax
20 kHz dual channel

Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs

Tachometer

Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection

Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape

Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input

Power supply to sensor
5 V, 50 mA

TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V

Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V

Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms

Accuracy 
± 0.1 %

Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required

Logging and Analysis

Output formats
LCD screen, Ascent, XML, System 1

Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory

Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names

Max folder size
10,000 measurement locations

Parameter Indication

Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage

Dynamic signal range
> 95 dB typical at 400 line resolution

Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower

Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB

Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart

Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading

High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.

AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz

Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)

Balancing

Planes
Up to 2 planes, 2 sensors

Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement

Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference

Remove trial weights
Yes/No Automatic recalculation

Manual data entry
Yes Allows re-entry of previous balance jobs

Storage
Against machines in data structure,No limits applied

Mechanical

Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap

Spectrum Display

Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X

Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.

Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements

Frequency scale
Hz, CPM, Orders, Linear scale with zooming

Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling

Window shapes
Hanning Rectangular

Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines

Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally

Averaging types
Linear, exponential, peak hold, synchronous

Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz

6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation

Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft

Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording

Display and Communication

Display
Graphic Grayscale LCD , White LED Backlight

Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight

Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese

Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware

USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive

Battery and Charger

Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh

Operating time
10 hours Backlight on — 60 second timeout

Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output

Charge rate
3 A nominal
3 hours for complete charge

Environmental Limits

Operating temperature
14 °F to 122 °F (-10 to 50 °C)

Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month

Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer and balancer. You can use this device for onroute data collection, machine-side analysis and diagnosis, and on-site dynamic balance correction. SCOUT100-Ex is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. This instrument is light but rugged and includes a neck strap with an integrated Sensor Keeper. The integrated Sensor Keeper retains your sensor while you walk orclimb to reach other machines.
$3,260.00
Bently Nevada SCOUT140-Ex Vibration Analyzer , Data Collector, Balancer - USED (SCOUT140-Ex)
The SCOUT140EX Vibration Data Collector, Analyzer and
Balancer is a portable hardware monitoring device that
supports four-channel vibration data collection, analysis,
and balancing. Use the device to collect data from sensors on
a route, for machine-side analysis and diagnosis, and on-site
dynamic balance correction.
The SCOUT140EX is ATEX Zone 2 and IECEx Zone 2 compliant
and safe for hazardous areas. It is both light and rugged. The
neck strap includes an integrated Sensor Keeper that
restrains your sensor while you walk or climb to reach other
machines.
The device includes a complete suite of advanced recording
and analysis capabilities, including tri-axial and 6Pack
recordings, coast-down, long time waveform, modal analysis
and cross channel spectrum (ODS).
The SCOUT140EX offers plenty of storage and long battery life.
The device comes with a five year warranty. It works with
System 1 software.
The SCOUT140EX Vibration Data Collector, Analyzer and
Balancer offers the following features:
l Up to four-channel, simultaneous on-route recordings
l Simultaneous acquisition, two-plane balancing with up
to four sensors
l Unique 6Pack recording system
l DC-coupled sensor support
l Support for acceleration, velocity, displacement, DCcoupled, current and voltage output sensors
l Triax-enabled
l One GB memory plus virtually unlimited spectra and
waveform storage 

SCOUT140-Ex comes with a full suite of advanced recording and
analysis capabilities including tri-axial and 6Pack recordings,
coast-down, long time waveform, modal analysis and cross
channel spectrum (ODS).
SCOUT140-Ex offers plenty of storage and long battery life. The
device is backed by five years of warranty.
SCOUT140-Ex is one of Bently Nevada hardware monitoring
assets that work with System 1* as well as Ascent* Level 2
software.

The SCOUT140EX Vibration Data Collector, Analyzer and Balancer is a portable hardware monitoring device that supports four-channel vibration data collection, analysis,and balancing. Use the device to collect data from sensors on a route, for machine-side analysis and diagnosis, and on-site dynamic balance correction.The SCOUT140EX is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. It is both light and rugged. The neck strap includes an integrated Sensor Keeper that restrains your sensor while you walk or climb to reach other machines.
$3,550.00
Bently Nevada SCOUT100-Ex Vibration Analyzer , Data Collector, Balancer - USED (SCOUT100-Ex)
The SCOUT100-EX Vibration Data Collector, Analyzer andBalancer is a portable hardware monitoring device thatsupports dual-channel vibration data collection, analysis, andbalancing. Use the device to collect data from sensors on aroute, for machine-side analysis and diagnosis, and on-sitedynamic balance correction.

The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.

The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.

The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:

- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years

Specifications

Sensors

Sensor input
Two Channels Simultaneous sampling

Compatible sensor types
Accelerometer, velocity,displacement, current

AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)

DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap

Connectors 
Safety feature: Break-free inline connector

Analog to digital conversion
24-bit ADC

Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer

Sensor detection
Warns if short circuit or not connected

Waveform Display

Number of samples
1024, 2048, 4096, 8192, 16,384

Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs

Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered

Long time waveform
25 Hz to 40 kHz

Fmax
20 kHz dual channel

Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs

Tachometer

Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection

Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape

Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input

Power supply to sensor
5 V, 50 mA

TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V

Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V

Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms

Accuracy 
± 0.1 %

Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required

Logging and Analysis

Output formats
LCD screen, Ascent, XML, System 1

Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory

Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names

Max folder size
10,000 measurement locations

Parameter Indication

Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage

Dynamic signal range
> 95 dB typical at 400 line resolution

Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower

Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB

Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart

Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading

High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.

AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz

Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)

Balancing

Planes
Up to 2 planes, 2 sensors

Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement

Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference

Remove trial weights
Yes/No Automatic recalculation

Manual data entry
Yes Allows re-entry of previous balance jobs

Storage
Against machines in data structure,No limits applied

Mechanical

Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap

Spectrum Display

Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X

Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.

Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements

Frequency scale
Hz, CPM, Orders, Linear scale with zooming

Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling

Window shapes
Hanning Rectangular

Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines

Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally

Averaging types
Linear, exponential, peak hold, synchronous

Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz

6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation

Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft

Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording

Display and Communication

Display
Graphic Grayscale LCD , White LED Backlight

Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight

Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese

Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware

USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive

Battery and Charger

Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh

Operating time
10 hours Backlight on — 60 second timeout

Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output

Charge rate
3 A nominal
3 hours for complete charge

Environmental Limits

Operating temperature
14 °F to 122 °F (-10 to 50 °C)

Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month

Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV

Also you can check product : Bently Nevada SCOUT100-Ex Vibration Analyzer , Data Collector, Balancer - NEW

SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer and balancer. You can use this device for onroute data collection, machine-side analysis and diagnosis, and on-site dynamic balance correction. SCOUT100-Ex is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. This instrument is light but rugged and includes a neck strap with an integrated Sensor Keeper. The integrated Sensor Keeper retains your sensor while you walk orclimb to reach other machines.
$2,180.00
Bently Nevada SCOUT200-IS Portable Vibration Analyzer and Data Collector - NEW (SCOUT200-IS)
DESCRIPTION

Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.

Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.

The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.

- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200

Hardware Features:

- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.

Software Features

- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.

Data Collector Specifications
Sensors

Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.

Compatible sensor types

Accelerometer, velocity,
displacement, and voltage.

AC coupled range

16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).

DC coupled ranges

0 to 20 V, -10 to 10 V, -20 to 0 V

Connectors

2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.

Analog to digital conversion

24-bit ADC

Sensor excitation current

0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors

Sensor detection

Measures sensor bias
voltage.
Warns if short circuit or not
connected.

Tachometer

Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.

Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.

Other sensor types supported
Contact, TTL Pulse, Keyphasor

Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.

Input Impedance & max values
100 KΩ
± 28 V max

Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy

Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable

Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)

Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)

Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).

Parameter Indication

Dynamic signal range
> 95 dB typical at 400 line resolution

Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.

Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS

Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart

Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)

High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.

AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz

Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).

Spectrum Display

Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.

Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.

Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200

Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.

Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.

Window shapes
Hanning, Rectangular

Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines

Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally

Averaging types
Linear, exponential, peak hold

Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz

6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation

Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768

Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs

Balancing

Planes 2 planes, 2 sensors

Speed Range 3 to 12,000 RPM

Measurement Type
Acceleration, Velocity,
Displacement

Weight modes
Angle 0° to 360°
Fixed Positions

Remove Trial Weights
Yes/No
Automatic recalculation

Storage
Balance jobs stored on
handheld and transferable
to System 1

Communication

Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)

Battery and Charger

Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.

Operating Time
10 hours typical on-route data
collection

Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.

Charge rate
2 A nominal 3 hours for complete charge.

Mechanical

Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )

Weight 1.5 lb ≈ 680g

Environmental Limits

Operating  temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas

Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)

Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.

Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65

S1 Collector App

Operating System
Android 5.1 to 12

Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish

Also you can check : Adash VIBRIO M Ex A4900 Vibration Analyzer and Data Collector - NEW

Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
$5,390.00
Bently Nevada SCOUT240-IS Portable Vibration Analyzer and Data Collector - NEW (SCOUT240-IS)
DESCRIPTION

Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.

Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.

The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.

- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200

Hardware Features:

- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.

Software Features

- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.

Data Collector Specifications
Sensors

Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.

Compatible sensor types

Accelerometer, velocity,
displacement, and voltage.

AC coupled range

16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).

DC coupled ranges

0 to 20 V, -10 to 10 V, -20 to 0 V

Connectors

2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.

Analog to digital conversion

24-bit ADC

Sensor excitation current

0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors

Sensor detection

Measures sensor bias
voltage.
Warns if short circuit or not
connected.

Tachometer

Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.

Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.

Other sensor types supported
Contact, TTL Pulse, Keyphasor

Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.

Input Impedance & max values
100 KΩ
± 28 V max

Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy

Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable

Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)

Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)

Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).

Parameter Indication

Dynamic signal range
> 95 dB typical at 400 line resolution

Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.

Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS

Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart

Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)

High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.

AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz

Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).

Spectrum Display

Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.

Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.

Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200

Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.

Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.

Window shapes
Hanning, Rectangular

Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines

Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally

Averaging types
Linear, exponential, peak hold

Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz

6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation

Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768

Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs

Balancing

Planes 2 planes, 2 sensors

Speed Range 3 to 12,000 RPM

Measurement Type
Acceleration, Velocity,
Displacement

Weight modes
Angle 0° to 360°
Fixed Positions

Remove Trial Weights
Yes/No
Automatic recalculation

Storage
Balance jobs stored on
handheld and transferable
to System 1

Communication

Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)

Battery and Charger

Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.

Operating Time
10 hours typical on-route data
collection

Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.

Charge rate
2 A nominal 3 hours for complete charge.

Mechanical

Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )

Weight 1.5 lb ≈ 680g

Environmental Limits

Operating  temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas

Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)

Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.

Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65

S1 Collector App

Operating System
Android 5.1 to 12

Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish

Also you can check : Bently Nevada SCOUT200-IS Portable Vibration Analyzer and Data Collector - NEW

Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
$5,690.00
Per Page      1 - 7 of 7
  • 1
Back to top