Giatec ICOR Wireless NDT Corrosion Detection - NEW
iCOR is the most advanced wireless corrosion measurement device for evaluating the health of reinforced concrete structures. iCOR detects corrosion potential, corrosion rate, and in-situ electrical resistivity. In 2019, the iCOR was presented the Corrosion Innovation Award by the National Association of Corrosion Engineers (NACE). Giatec ICOR is a unique non-destructive testing tool for detailed detection and evaluation of corrosion in reinforced concrete structures without the need to have an electrical connection to the rebar.
$5,240.00
Non-Invasive & Non-Destructive Wireless Technology
Unlike other devices which must drill into the concrete and physically connect to the rebar to evaluate corrosion, the iCOR® is completely non-destructive.
Fast & Accurate Real-Time Data in Seconds
Data is collected, analyzed, and stored wirelessly within the mobile app on the tablet provided where it can be easily shared with team members.
Automatic Report Generation Simple & Easy-To-Use
Detailed corrosion evaluation of reinforced concrete structures is presented as contour maps which are accessible in real-time on the tablet.
Recipient of NACE Corrosion Innovation Award
iCOR is the most advanced wireless corrosion measurement device for evaluating the health of reinforced concrete structures. iCOR detects corrosion potential, corrosion rate, and in-situ electrical resistivity. In 2019, the iCOR was presented the Corrosion Innovation Award by the National Association of Corrosion Engineers (NACE).
Applications
Detection of corrosion in reinforcement
Measurement of rebar corrosion rate
Evaluation of corrosion potential of rebar
Measurement of in-situ electrical resistivity
Assessment of concrete durability
Rehabilitation and repair of concrete structures
Software
Real-time contour mapping of corrosion rate, electrical resistivity, and corrosion potential
Accurate non-subjective algorithm-based interpretations
Multiple and directional parameters tested in a single measurement
Easy reporting and data exporting
Hardware
Non-destructive, and non-invasive wireless technology
Measurements obtained and evaluated within seconds
Simple and easy-to-use with minimal training required
Single-person operation device
Tablet included with free Android app
Award-winning patented technology
Patented Technology
iCOR benefits from the patented CEPRA technology that makes it possible to estimate the rate of rebar corrosion through a noninvasive, non-destructive approach. This means that the need to connect the device to the rebar to obtain measurements, which is the case for other commercial devices, is eliminated with the iCOR.
TECHNICAL SPECIFICATIONS :
Testing Time 3 to 30 seconds
Corrosion Rate Range 0 to 500 μm / year
Corrosion Potential Range -800 to 200 mV / CSE
Electrical Resistivity Range 0 to 10,000 Ω • m
Operating Temperature 32 to 113°F (0 ~ 45°C)
Operating Humidity 20~ 90% RH
Dimensions 250 x 70mm
Weight 900g
INCLUDED :
Beta unit, Tablet with hands-free carrying support, Data Analysis App., User manual, Connection sponges, USB cable, Conductive solution, Carrying Case.
Unlike other devices which must drill into the concrete and physically connect to the rebar to evaluate corrosion, the iCOR® is completely non-destructive.
Fast & Accurate Real-Time Data in Seconds
Data is collected, analyzed, and stored wirelessly within the mobile app on the tablet provided where it can be easily shared with team members.
Automatic Report Generation Simple & Easy-To-Use
Detailed corrosion evaluation of reinforced concrete structures is presented as contour maps which are accessible in real-time on the tablet.
Recipient of NACE Corrosion Innovation Award
iCOR is the most advanced wireless corrosion measurement device for evaluating the health of reinforced concrete structures. iCOR detects corrosion potential, corrosion rate, and in-situ electrical resistivity. In 2019, the iCOR was presented the Corrosion Innovation Award by the National Association of Corrosion Engineers (NACE).
Applications
Detection of corrosion in reinforcement
Measurement of rebar corrosion rate
Evaluation of corrosion potential of rebar
Measurement of in-situ electrical resistivity
Assessment of concrete durability
Rehabilitation and repair of concrete structures
Software
Real-time contour mapping of corrosion rate, electrical resistivity, and corrosion potential
Accurate non-subjective algorithm-based interpretations
Multiple and directional parameters tested in a single measurement
Easy reporting and data exporting
Hardware
Non-destructive, and non-invasive wireless technology
Measurements obtained and evaluated within seconds
Simple and easy-to-use with minimal training required
Single-person operation device
Tablet included with free Android app
Award-winning patented technology
Patented Technology
iCOR benefits from the patented CEPRA technology that makes it possible to estimate the rate of rebar corrosion through a noninvasive, non-destructive approach. This means that the need to connect the device to the rebar to obtain measurements, which is the case for other commercial devices, is eliminated with the iCOR.
TECHNICAL SPECIFICATIONS :
Testing Time 3 to 30 seconds
Corrosion Rate Range 0 to 500 μm / year
Corrosion Potential Range -800 to 200 mV / CSE
Electrical Resistivity Range 0 to 10,000 Ω • m
Operating Temperature 32 to 113°F (0 ~ 45°C)
Operating Humidity 20~ 90% RH
Dimensions 250 x 70mm
Weight 900g
INCLUDED :