Bently Nevada SCOUT100-Ex Vibration Analyzer , Data Collector, Balancer - NEW
SCOUT100-Ex is a portable dual-channel vibration data collector, analyzer and balancer. You can use this device for onroute data collection, machine-side analysis and diagnosis, and on-site dynamic balance correction. SCOUT100-Ex is ATEX Zone 2 and IECEx Zone 2 compliant and safe for hazardous areas. This instrument is light but rugged and includes a neck strap with an integrated Sensor Keeper. The integrated Sensor Keeper retains your sensor while you walk orclimb to reach other machines.
$3,260.00
The SCOUT100-EX Vibration Data Collector, Analyzer andBalancer is a portable hardware monitoring device thatsupports dual-channel vibration data collection, analysis, andbalancing. Use the device to collect data from sensors on aroute, for machine-side analysis and diagnosis, and on-sitedynamic balance correction.
The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV