Bently Nevada SCOUT240-IS Portable Vibration Analyzer and Data Collector - NEW
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
$5,690.00
DESCRIPTION
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.
The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.
- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200
Hardware Features:
- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.
Software Features
- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.
Data Collector Specifications
Sensors
Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.
Compatible sensor types
Accelerometer, velocity,
displacement, and voltage.
AC coupled range
16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).
DC coupled ranges
0 to 20 V, -10 to 10 V, -20 to 0 V
Connectors
2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors
Sensor detection
Measures sensor bias
voltage.
Warns if short circuit or not
connected.
Tachometer
Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.
Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.
Input Impedance & max values
100 KΩ
± 28 V max
Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy
Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable
Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)
Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)
Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).
Parameter Indication
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.
Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS
Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart
Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)
High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz
Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).
Spectrum Display
Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.
Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.
Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200
Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.
Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.
Window shapes
Hanning, Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally
Averaging types
Linear, exponential, peak hold
Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz
6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation
Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768
Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs
Balancing
Planes 2 planes, 2 sensors
Speed Range 3 to 12,000 RPM
Measurement Type
Acceleration, Velocity,
Displacement
Weight modes
Angle 0° to 360°
Fixed Positions
Remove Trial Weights
Yes/No
Automatic recalculation
Storage
Balance jobs stored on
handheld and transferable
to System 1
Communication
Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.
Operating Time
10 hours typical on-route data
collection
Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.
Charge rate
2 A nominal 3 hours for complete charge.
Mechanical
Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )
Weight 1.5 lb ≈ 680g
Environmental Limits
Operating temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas
Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)
Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.
Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65
S1 Collector App
Operating System
Android 5.1 to 12
Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish
Also you can check : Bently Nevada SCOUT200-IS Portable Vibration Analyzer and Data Collector - NEW
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.
The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.
- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200
Hardware Features:
- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.
Software Features
- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.
Data Collector Specifications
Sensors
Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.
Compatible sensor types
Accelerometer, velocity,
displacement, and voltage.
AC coupled range
16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).
DC coupled ranges
0 to 20 V, -10 to 10 V, -20 to 0 V
Connectors
2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors
Sensor detection
Measures sensor bias
voltage.
Warns if short circuit or not
connected.
Tachometer
Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.
Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.
Input Impedance & max values
100 KΩ
± 28 V max
Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy
Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable
Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)
Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)
Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).
Parameter Indication
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.
Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS
Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart
Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)
High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz
Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).
Spectrum Display
Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.
Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.
Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200
Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.
Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.
Window shapes
Hanning, Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally
Averaging types
Linear, exponential, peak hold
Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz
6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation
Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768
Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs
Balancing
Planes 2 planes, 2 sensors
Speed Range 3 to 12,000 RPM
Measurement Type
Acceleration, Velocity,
Displacement
Weight modes
Angle 0° to 360°
Fixed Positions
Remove Trial Weights
Yes/No
Automatic recalculation
Storage
Balance jobs stored on
handheld and transferable
to System 1
Communication
Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.
Operating Time
10 hours typical on-route data
collection
Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.
Charge rate
2 A nominal 3 hours for complete charge.
Mechanical
Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )
Weight 1.5 lb ≈ 680g
Environmental Limits
Operating temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas
Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)
Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.
Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65
S1 Collector App
Operating System
Android 5.1 to 12
Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish
Also you can check : Bently Nevada SCOUT200-IS Portable Vibration Analyzer and Data Collector - NEW