Skf CMXA80 Microlog Vibration Analyzer - USED
SKF CMXA80-F-K-SL Portable Data Collector/ FFT Analyzer is the SKF Microlog Analyzer AX is the most advanced large screen route based analyzer offered by SKF today. The SKF Microlog AX’s features allow you to capture a wide range of vibration data quickly. The analyzer provides the flexibility to support applications that are most important to your company’s specific predictive mainte- nance program. Developed for use in a wide range of industries, the SKF Microlog AX series is approved for use in hazardous environ- ments requiring ATEX, IECEx and Class I Division 2 certifications.SKF CMXA80-F-K-SL Portable Data Collector/ FFT Analyzer is the SKF Microlog Analyzer AX is the most advanced large screen route based analyzer offered by SKF today. The SKF Microlog AX’s features allow you to capture a wide range of vibration data quickly. The analyzer provides the flexibility to support applications that are most important to your company’s specific predictive mainte- nance program. Developed for use in a wide range of industries, the SKF Microlog AX series is approved for use in hazardous environ- ments requiring ATEX, IECEx and Class I Division 2 certifications.
SPECIFICATIONS :
Performance characteristics
Acceleration, velocity, and displacement from hand-held or installed vibration sensors or monitoring systems • AC / DC sensors
• Pressure sensors
• Temperature sensors
• Keyboard entry: Measurements read from indicators or installed instruments entered in engineering units
• Universal tachometer
• Visual inspections: Added to measurement as coded notes
Enveloper (demodulator) With four selectable input filters for enhanced bearing and gear mesh fault detection
gE filter selections • 5 Hz to 100 Hz
• 50 Hz to 1 kHz
• 500 Hz to 10 kHz
• 5 kHz to 40 kHz
Input parameters • Tachometer: TTL / analogue programmable to ±25 V
• RPM range 1 to 99 999
• Tachometer power supply output 5 V at 100 mA
Input over-voltage protection • AC ±50 V peak
• DC ±50 V sustained
Dynamic range >90 dB (24 bit ADC sigma-delta)
Input connectors • CH1: Six pin Fischer CH1, CH2, CH3, CH4 (labeled R) (ICP/AC/DC input), strobe out
• CH2: Six pin Fischer CH2 and CH3 (ICP/AC/ DC input), 5 V tachometer out
• USB HOST/CHR: Seven pin Fischer R (ICP/AC/ DC input), USB HOST, audio out
• USB DEV/TRIG/PWR: Seven pin Fischer USB DEV, charger, external trigger aux, 5 V tachometer out
Input signal range ±25 V maximum
Signal RMS/Peak/Peak-Peak/True Peak/True Peak-Peak
Transducer check Bias Voltage Integrity (O/C and S/C detection)
Auto range Yes
Frequency range DC to 80 kHz
Bearing condition gE
FFT resolution 100 to 25 600 lines
Time block length 256 to 65 536 samples
Alarms Overall, Spectrum and Exponential (Peak and RMS level)
Measurement
Range • Route measurements: DC to 80 kHz
• Non-route measurements: DC to 80 kHz
Averaging 1 to 255 time averages, 1 to 4 096 spectral averages
Averaging type RMS, Time, Peak Hold, Exponential
Cursor Fixed and cursor lock. Single, har monic and peak pick.
Trigger modes Free run or external trig ger (trigger slope and amplitude)
Resolution Programmable 100, 200, 400, 800, 1 600, 3 200, 6 400, 12 800 and 25 600 lines
Measurement windows Hanning, flat top, hamming and rectangular
Measurement parameters Acceleration, velocity, displacement, gE, temperature, phase, voltage, user specified
Measurement types Overall, spectrum, time waveform, cross phase, orbits, shaft centerline
Multi-point automation Up to 12 meas urements can be listed for one button push automated data collection at each measurement location
Accuracy ±2.5% of full scale range
Data display • Single and dual channel spectrum, single and dual channel time, phase table, process, orbit, cross channel phase
• Simultaneous spectrum, time waveform, peak hold averaging
• Up to 12 bands (fixed or order base) downloadable from host software
Power
Battery • Li-ion smart battery pack
• Eight hours continuous operation minimum
Physical data
Dedicated keys Up, down, right, and left two enter keys for right and left hand operation, four function keys
Hot keys Peak find, harmonic, expand
LCD screen 6.4 in. VGA color transflective TFT LCD screen for indoor and outdoor use, 640 ™ 480 pixels resolution, 16-bit color
Case EN60529, IP 65 (dust- and waterproof)
Weight 1, 6 kg (3.5 lb.)
Size (height ™ width) 220 ™ 220 ™ 71 mm (8.7 ™ 8.7 ™ 2.8 in.)
Drop test 1.2 m (4 ft.), to MIL STD 810F specifications (with stand retracted)
Environmental
Certifications • Special conditions per certifications
• ATEX: II 3 G Ex ic IIC T4 Gc (Ta = –10 °C to 50 °C)
• IECEx: Ex ic IIC T4 Gc (Ta = –10 °C to 50 °C)
• CE rated
• CSA, Class I, Division 2, Groups A, B, C, D, temperature code T4@Ta = 50 °C
IP Rating IP 65
Temperature ratings • Operating temperature: –10 to 50 °C (14 to 122 °F)
• Storage temperature: –20 to 60 °C (–4 to 140 °F)
Humidity 10 to 90% relative humidity, non-condensing at 0 to 50 °C (32 to 122 °F)
Vibration MIL STD 810 transportation
System, data processing and storage
Operating system Microsoft Windows Embedded CE 6.0
Processor Marvell PXA320 806 MH
DSP Freescale DSP56311
Internal RAM • 128 MB DDR SDRAM
• 128 MB NAND Flash
Internal storage 120 MB (capable of storing approximately 4 000 spectra)
SD card Can support up to 16 GB
Communication USB
User indicator Blue, green, amber and red LED’s
Host software
Software The SKF Microlog GX series connects directly to SKF @ptitude Analyst for SKF Microlog software.
The Analysis and Reporting Manager plug-in to SKF @ptitude Analyst provides support for the SKF Microlog application modules.