Vibration Analyzer
VA can use the units of Displacement, Velocity and Acceleration displayed as a time waveform (TWF), but most commonly the spectrum is used, derived from a fast Fourier transform of the TWF. The vibration spectrum provides important frequency information that can pinpoint the faulty component.
The fundamentals of vibration analysis can be understood by studying the simple Mass-spring-damper model. Indeed, even a complex structure such as an automobile body can be modeled as a "summation" of simple mass–spring–damper models. The mass–spring–damper model is an example of a simple harmonic oscillator. The mathematics used to describe its behavior is identical to other simple harmonic oscillators such as the RLC circuit.
Note: This article does not include the step-by-step mathematical derivations, but focuses on major vibration analysis equations and concepts. Please refer to the references at the end of the article for detailed derivations.
State-of-the-art technology
With a robust, high-speed data processor, the SKF Microlog GX series captures full feature route and non-route dynamic (vibration) and static (process) measurements from many sources. Fixed mode autoranging automatically selects an input range based on the sensor type and sensitivity. Three channel simultaneous triaxial input with the separate tachometer input enables faster, more comprehensive data collection without adding to collection time. The SKF Microlog GX series also includes a triggering functionality that enables the unit to examine the trigger signal first, and then automatically set the trigger level. For even faster data collection, users can configure up to 12 measurements for automatic, one button data collection at a measurement location.
Modular approach offers seamless expansion
The modular design of the SKF Microlog GX series offers customers the option to upgrade and expand functionality without having to buy another instrument. Accessories are inter-changeable between models. The SKF Microlog GX is shipped with the full SKF Microlog suite of modules installed. To add additional functionality, units can be upgraded to more advanced models, simply purchase the module and enter the supplied license key.
For companies who are interested in an entry-level route-based data collector, the SKF Microlog GX-R model offers ease of use and implementation with multi-route, single channel data collection. This model features a measurement range of 80 kHz F max and up to 25 600 FFT lines of resolution.
SKF Microlog GX-M includes multiple routes, and non-route data collection, four channel FFT analysis, three channel simultaneous triax and the Balancing module.
Additional features are added to create the SKF Microlog GX-F model, which includes all modules. The SKF Microlog GX-M can also be upgraded to any of the other modules including Run up Coast down module that is used to record and analyze data from machines where noise or vibration levels are changing with speed or time, and the Frequency Response Function (FRF) module, which uses a modal hammer to establish the properties of mechanical structures.
Asset data available fast, enterprise wide and in the formats you want
The route based SKF Microlog GX series transfers data to SKF @ptitude Analyst software, a comprehensive software solution with powerful diagnostic and analytical capabilities. SKF @ptitude Analyst provides fast, efficient and reliable storage, analysis, and retrieval of complex asset information and makes the information accessible throughout your entire organization.
With this powerful analysis tool, you are in complete control – from the way you set up hierarchies, filtered workspaces, routes, and analysis parameters, to the customized format for reporting. You can collect information based on location, machine type, frequency, or other selections. SKF @ptitude Analyst allows you to determine the appropriate limits for alarm conditions and how alarms are categorized.
You receive consistent, reliable data in the format that suits you best. SKF @ptitude Analyst can incorporate data from other sources, such as OPC servers, and seamlessly interface with your organization’s Computerized Maintenance Management System (CMMS), Enterprise Resource Planning (ERP) or other information management systems.
Features :
- Marvell 806 MHz PXA320 processor for exceptionally fast operation
- Bright 1 / 4 VGA color display that enhances visibility in all environ – ments – dark or bright
- Rugged design – Two meter multiple drop – IP 65 rated
- Outstanding data storage capacity with 128 MB flash memory for internal storage and Secure Digital (SD) memory expansion slot
- Multi-language support – 15 language options
- Choose between instruments that have single channel input, or four channels plus simultaneous triaxial input
- Multi-plane balancing application
- Intuitive graphical user interface
- Long-life battery for up to eight hours of operation
- Wide range of accessories to expand functionality even further
- Field upgradeable from an entry level instrument to an advanced analyzer
What’s In The Box :
- (1) CD-ROM, user manuals, utilities, asset information page, and literature
- (1) USB communication / power splitter straight cable, 2 m (6.6 ft.) [CMAC 5095]
- (1) Battery pack [CMAC 5031]
- (1) Universal power supply [CMAC 5090]
- (1) Rubber bump sleeve [CMAC 5015]
- (1) Hard shell carrying case [CMAC 5029]
- (1) Hand strap [CMAC 5020]
- (1) Shoulder strap [CMAC 5010]
- (1) Shoulder strap for ATEX units [CMAC 5113]
- (2) Screen protectors 1, 2)
- (1) Connector cover set with lanyards
- (1)4 GB SD card [CMAC 5077]
Features :
All basic vibrodiagnostics measurements:
Overall values, Time signal, Frequency bands, FFT Spectrum, Route measurement
4 MB memory for data storage
detects unbalance, loosenes, misalignment or bearing faults
ISO 10816-3 included
8 hours of operation
stroboscope LED-lamp for machine check
available in intrinsically safe version A4900 Vibrio M Ex
SPECS :
Input: 1 x ICP powered accelerometer
Input range : 60 g PEAK with standard 100 mV/g sensor
(e.g. 600 g PEAK for 10 mV/g sensor, the sensitivity is editable in the unit)
Measurements: Velocity RMS: 10 - 1 000 Hz [mm/s, ips]
Velocity PEAK: 10 - 1 000 Hz [mm/s, ips]
Acceleration RMS: 500 - 16 000 Hz [g]
Acceleration Peak: 500 - 16 000 Hz [g]
Velocity time: 1 - 1 000 Hz [mm/s, ips], 2048 samples *
Velocity spectrum: 1 - 1 000 Hz [mm/s, ips], 800 lines
Acceleration time: 1 - 16 000 Hz [g], 2048 samples*
Acceleration spectrum: 1 - 16 000 Hz [g], 800 lines*
Acceleration Demod-Envelope RMS: 500 - 16 000 Hz [g]
Acceleration Demod-Envelope Peak: 500 - 16 000 Hz [g]*
Acceleration Demod-Envelope time: 500 - 16 000 Hz [g], 2048 samples
Acceleration Demod-Envelope spectrum: 500 - 16 000 Hz [g], 800 lines,
range 400 Hz*
Displacement RMS: 2 - 100 Hz [µm, mil]
Displacement 0-Peak: 2 - 100 Hz [µm, mil]
Displacement Peak-Peak: 2 - 100 Hz [µm, mil]
Temperature non-contact measurement: 0 - 380°C (32 - 716°F)
Other functions: LED stroboscope (0.17-300 Hz, 10 - 18 000 RPM)
LED torch
Vibration stethoscope
Memory: 4 MB for data
900 measurements of 800 line spectra or 2048 sample time signals
may be stored
Data storing: Off-Route
Route with DDS software for Vibrio M (free download)
Interface: USB 2.0 compatible
Software: Free version of DDS software (limited database size)
Display: Colour graphic OLED display 128x128 pixels, diagonal 1.5“ (38 mm)
Output: 1 x AC signal 8 Ω / 0,5 W for external headphones (signal listening)
Power: 2 x AA 1.5V batteries (alkaline, NiMH, Lithium - 8 hours of operation)
Temperature: Operating: -5°C to 55°C
Dimensions: 150 x 60 x 35 mm
Weight: 330 g including batteries (without cable, sensor and magnet)
540 g including batteries, cable, sensor and magnet
Accessories: vibration sensor, coiled cable to connect vibration sensor, magnetic base
for vibration sensor, headphones with 3.5 mm jack, USB cable, measuring
tip for manual pressure on the sensor, transport case, USB flash disc with
the manual
What’s in the Box :
(1) Vibration sensor
(1) Coiled cable to connect vibration sensor
(1) Magnetic base for vibration sensor
(1) Headphones with 3.5 mm jack
(1) USB cable
(1) Measuring tip for manual pressure on the sensor
(1) Transport case
(1) USB flash disc with the manual
(2) AA 1.5V batteries
Also you can check : Adash A4500 VA5 Pro Vibration Analyzer - Thermal Imaging - Ultrasound - NEW
SKF CMXA80-F-K-SL Portable Data Collector/ FFT Analyzer is the SKF Microlog Analyzer AX is the most advanced large screen route based analyzer offered by SKF today. The SKF Microlog AX’s features allow you to capture a wide range of vibration data quickly. The analyzer provides the flexibility to support applications that are most important to your company’s specific predictive mainte- nance program. Developed for use in a wide range of industries, the SKF Microlog AX series is approved for use in hazardous environ- ments requiring ATEX, IECEx and Class I Division 2 certifications.
SPECIFICATIONS :
Performance characteristics
Acceleration, velocity, and displacement from hand-held or installed vibration sensors or monitoring systems • AC / DC sensors
• Pressure sensors
• Temperature sensors
• Keyboard entry: Measurements read from indicators or installed instruments entered in engineering units
• Universal tachometer
• Visual inspections: Added to measurement as coded notes
Enveloper (demodulator) With four selectable input filters for enhanced bearing and gear mesh fault detection
gE filter selections • 5 Hz to 100 Hz
• 50 Hz to 1 kHz
• 500 Hz to 10 kHz
• 5 kHz to 40 kHz
Input parameters • Tachometer: TTL / analogue programmable to ±25 V
• RPM range 1 to 99 999
• Tachometer power supply output 5 V at 100 mA
Input over-voltage protection • AC ±50 V peak
• DC ±50 V sustained
Dynamic range >90 dB (24 bit ADC sigma-delta)
Input connectors • CH1: Six pin Fischer CH1, CH2, CH3, CH4 (labeled R) (ICP/AC/DC input), strobe out
• CH2: Six pin Fischer CH2 and CH3 (ICP/AC/ DC input), 5 V tachometer out
• USB HOST/CHR: Seven pin Fischer R (ICP/AC/ DC input), USB HOST, audio out
• USB DEV/TRIG/PWR: Seven pin Fischer USB DEV, charger, external trigger aux, 5 V tachometer out
Input signal range ±25 V maximum
Signal RMS/Peak/Peak-Peak/True Peak/True Peak-Peak
Transducer check Bias Voltage Integrity (O/C and S/C detection)
Auto range Yes
Frequency range DC to 80 kHz
Bearing condition gE
FFT resolution 100 to 25 600 lines
Time block length 256 to 65 536 samples
Alarms Overall, Spectrum and Exponential (Peak and RMS level)
Measurement
Range • Route measurements: DC to 80 kHz
• Non-route measurements: DC to 80 kHz
Averaging 1 to 255 time averages, 1 to 4 096 spectral averages
Averaging type RMS, Time, Peak Hold, Exponential
Cursor Fixed and cursor lock. Single, har monic and peak pick.
Trigger modes Free run or external trig ger (trigger slope and amplitude)
Resolution Programmable 100, 200, 400, 800, 1 600, 3 200, 6 400, 12 800 and 25 600 lines
Measurement windows Hanning, flat top, hamming and rectangular
Measurement parameters Acceleration, velocity, displacement, gE, temperature, phase, voltage, user specified
Measurement types Overall, spectrum, time waveform, cross phase, orbits, shaft centerline
Multi-point automation Up to 12 meas urements can be listed for one button push automated data collection at each measurement location
Accuracy ±2.5% of full scale range
Data display • Single and dual channel spectrum, single and dual channel time, phase table, process, orbit, cross channel phase
• Simultaneous spectrum, time waveform, peak hold averaging
• Up to 12 bands (fixed or order base) downloadable from host software
Power
Battery • Li-ion smart battery pack
• Eight hours continuous operation minimum
Physical data
Dedicated keys Up, down, right, and left two enter keys for right and left hand operation, four function keys
Hot keys Peak find, harmonic, expand
LCD screen 6.4 in. VGA color transflective TFT LCD screen for indoor and outdoor use, 640 ™ 480 pixels resolution, 16-bit color
Case EN60529, IP 65 (dust- and waterproof)
Weight 1, 6 kg (3.5 lb.)
Size (height ™ width) 220 ™ 220 ™ 71 mm (8.7 ™ 8.7 ™ 2.8 in.)
Drop test 1.2 m (4 ft.), to MIL STD 810F specifications (with stand retracted)
Environmental
Certifications • Special conditions per certifications
• ATEX: II 3 G Ex ic IIC T4 Gc (Ta = –10 °C to 50 °C)
• IECEx: Ex ic IIC T4 Gc (Ta = –10 °C to 50 °C)
• CE rated
• CSA, Class I, Division 2, Groups A, B, C, D, temperature code T4@Ta = 50 °C
IP Rating IP 65
Temperature ratings • Operating temperature: –10 to 50 °C (14 to 122 °F)
• Storage temperature: –20 to 60 °C (–4 to 140 °F)
Humidity 10 to 90% relative humidity, non-condensing at 0 to 50 °C (32 to 122 °F)
Vibration MIL STD 810 transportation
System, data processing and storage
Operating system Microsoft Windows Embedded CE 6.0
Processor Marvell PXA320 806 MH
DSP Freescale DSP56311
Internal RAM • 128 MB DDR SDRAM
• 128 MB NAND Flash
Internal storage 120 MB (capable of storing approximately 4 000 spectra)
SD card Can support up to 16 GB
Communication USB
User indicator Blue, green, amber and red LED’s
Host software
Software The SKF Microlog GX series connects directly to SKF @ptitude Analyst for SKF Microlog software.
The Analysis and Reporting Manager plug-in to SKF @ptitude Analyst provides support for the SKF Microlog application modules.
Explore the most powerful Vibration Analyzer on the market.
Use multitasking tool in order to analyse your machinery.
Balancer, Thermal imaging camera, Ultrasound, Bump test, ODS, MCSA – you name it…
Measure 4 vibration signals and 4 process values (temperature, pressure etc.) along with speed synchronously. Triaxial sensor friendly, proximity probes for displacement measurement, ultrasound microphone, acoustic microphone, thermal imaging camera, current clamp meter, stethoscope and more.
Adash America A4500 PRO - Vibration Analyzer, VA5 Pro Package
- FFT with UP to 3 276 800 lines
- 90 kHz frequency range
- Raw signal recording
- 8 Channel signal analyzer
Enjoy a huge touchscreen to analyze your machinery on site. Measure 4 vibration signal channels and 4 process value channels (temperature, pressure etc.) along with speed synchronously. Triaxial sensor friendly, proximity probes for displacement measurement ready, balancer, octave analysis, bump test, ODS, MCSA
8 Channel Signal Analyzer
- 4 AC inputs for vibration measurement
- 4 DC inputs for process values measurement
- Tacho input (speed/trigger)
Multi-Tasking Anaylzer
The VA5PRO allows you to measure more measurement types synchronously. Overall values, FFTs, Time waveforms.
You can hear it
Ultrasound microphone for leak detaction
You can see it
Thermal imaging camera
The Bently Nevada VB Series Condition Monitors are built to robust professional standards, making them the first choice for numerous leading companies around the world. Featuring powerful, condition monitoring software, this tiered instrument range varies in features and price, enabling you to select the model with the set of features you require. The VB Series models are rated for CSA Class 1, Division 2.
The vb7 instrument is a portable dual channel vibration data collector, analyzer and balancer. You can use this device for onroute and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb7 is certified for Class 1Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb7 provides recordings with up to 6,400 lines of resolution and up to 40 kHz Fmax. Our patented adaptive settling algorithm and 6Pack recording system offer quick, one-step data recording.
The vb8 instrument is a portable four-channel vibration data collector, analyzer and balancer. You can use this device for on route and off-route data collection, machine-side analysis and diagnosis as well as on-site dynamic balance correction. The vb8 is certified for Class 1Division 2 hazardous areas. It is ergonomically designed and lightweight for all day comfort. The vb8 provides recordings with up to 12,800 lines of resolution and up to 80 kHz Fmax. Our patented adaptive settling algorithm and 6 Pack recording system offer quick, one-step data recording.
Features
Dual or four channel models
Measurement range (1,000 g, 25,000 mm/s, 2,500mm)
Tachometer input
40 kHz Fmax (vb7) or 80 kHz Fmax (vb8)
6,400 or 12,800 lines FFT resolution
Two-place balancing
≥ 95 dB dynamic range
Spectrum and waveform recordings
1GB memory and virtually unlimited spectra storage
Integration with System 1 Condition Monitoring and Diagnostic software
INCLUDED :
Bently Nevada Commtest Transducer Cable
Bently Nevada Commtest Laser Tachometer Cable
Bently Nevada Commtest Triple BNC Cable
Bently Nevada Commtest Accelerometer Straight Cable (Green)
Bently Nevada Commtest Accelerometer Straight Cable (Red)
Frontier Wireless Sensor Kit
Bently Nevada vbX Battery Pack
Bently Nevada Commtest Carry Bag
Bently Nevada Commtest Dustcover
Bently Nevada Commtest Keyphasor Tachometer Cable
Bently Nevada Commtest 2-Channel Balancing Kit
Bently Nevada Commtest 4-Channel Balancing Kit
Bently Nevada Commtest Laser Tachometer
Bently Nevada Commtest Laser Tachometer and Block
Bently Nevada Commtest Laser Tachometer Magnetic Base
Bently Nevada Commtest Accelerometer Magnetic Base (Female)
Bently Nevada Commtest Accelerometer Magnetic Base (Male)
Bently Nevada Commtest Safety Rings
Bently Nevada Commtest 780A-IS Accelerometer
Bently Nevada Commtest 787A-IS Accelerometer
Bently Nevada Commtest Power Supply
Bently Nevada S1 Remote Training for Portables
Bently Nevada Neck Strap
SPECS :
Sensor input
2 channels
Compatible sensor types
Accelerometer, velocity, displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output swing (± 80 g)
DC coupled ranges
0 V to 20 V, -10 V to 10 V, -20 V to 0 V
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable), 24 V maximum
Laser sensor range
10 cm to 2 m nominal
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min, 28 V (5 mA) max, off-state 0.8 V
Speed range
10 to 300 000 RPM (0.2 to 5 kHz)
Output to drive strobe
Up to 140 Hz (8400 CPM)
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz up to 16 kHz to 20 kHz
Long time waveform Fmax
25 Hz to 40 kHz
Dimensions (W x L x H)
9.9” x 5.8” x 2.4” (252 x 148 x 60) mm
Weight
2.7 lb. (1.2 kg)
Operating temperature
14°F to 122°F (-10°C to 50°C)
Includes :
COMM-CBCC0027 | BNC adapter cable
COMM-CBVB0032 | Carry Case
GENE-12V-3.0A | Power supply
GENE-PC-10A/125V | Power Cord
GENE-CAR-ADAPT01 | Car Charger for cigarette lighter
GENE-USB | USB Cable, Type A to Type B, 6'
COMM-NSSK0275 | Neck Strap with Sensor Keeper
COMM-BATT0206 | Battery Pack (installed)
COMM-VB7-COIL-CBL01 | Accelometer Coiled Cable
COMM-MVBX0250 | vbSeries Instrument Reference Guide
COMM-VB7-QSG01 | Quick Start Guide
COMM-VB*-CD01 | Implementation Success Training CD
WILC-780A-IS-NR | Accelerometer 5% tolerance and a broad 3dB frequency response from 0.4 Hz to 14 kHz
COMM-VB7-MBS01 | Magnetic Base with Adjustable Stand
COMM-L766 | Tachometer Extension Cable, 5 meter
COMM-CB5R0025 | BNC Extension Cable, 5 meter (red)
COMM-VB-CASE02 | Accessory Bag
COMM-LASA0315 | Laser tachometer
COMM-CB5G0024 | BNC Extension Cable, 5 meter (green)
DELL-LATITUDE-D620 | 2GB RAM, RS232 Interface, Windows XP Pro Laptop Computer
DELL-AA22850 | 65W AC/DC Adapter 19.5V 3.34A Output w/F2951 Power Cord
COMM-VB-R-TAPE01 | Reflective Tape
COMM-VB*-CD02 | Ascent Reference Guide CD
COMM-MAGM0064 | Accelometer Magnetic Base, Male
The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
The A4400 instrument contains these measurement modes:
Measurement of 4 channel simultaneously gives a lot of flexibility in fault diagnosis. For instance, you can get a good insight of the alignment by measuring the radial and axial vibration across the coupling of the motor and pump. 120Gb allows 35 hours continuous recording of 4 channel raw signals up to 25.6kHz, so you can make the diagnosis later; and won't miss any transient behavior of the machine. |
Simultaneous Measurement |
Multi-measurements can be measured in parallel for a single measurement point, which save time; and improve consistency in data especially when the machine speed or running condition varies with time.
|
Balancing |
|
Data Collector |
A4400 VA4Pro can be used as a Data Collector for routine data collection. |
Run-up / Coast Down |
Run-up / Coast-down can be easily carried out on A4400 VA4Pro. Raw time data can also be recorded as a backup for critical machine. 4 DC Process Parameters can be measured at the same time for correlation analysis with vibration readings.
|
Software DDS 2010 |
One software for all instruments! The Adash Ltd. keeps one rule all the time from 1991. The measured data from any instrument (portable or on-line) are saved in one data format to the database. It enables to use just one data acquisition software. The software system DDS 2011 contains all functions, which are necessary for next data analysis. Main features:
|
The Adash A4400 VA4 Pro CMS PRO Balance Kit includes functionality for Data Collection, Run-up Analyzer, Balancer, Recorder, FASIT, Stethoscope, Lubri and Octive Analyzer in one unit! System includes: |
|
|
VIBXPERT II platform, which is used worldwide by many technicians
for mobile data acquisition and signal analysis.
The 'Balancer' is distinguished by its efficiency and ease of use. The
measurement process implemented in the instrument is based on the
well-known "influencing coefficients method" and has been optimized
by a new knowledge-based algorithm. In addition to the balancing
procedure, VIBXPERT II allows vibration analyzes, resonance tests
and phase measurements to support the diagnosis of an imbalance
and to determine the optimum operating conditions for the rotor.
Application
• Field balancing in one or two planes
• Vibration analysis
• Resonance test
Analysis
• Overall value and process parameter
• Time waveform
• Amplitude spectrum
• Envelope spectrum (acceleration)
• Phase measurement, incl. recording
• Impact test (1-channel)
• Coast-down/ Run-up test (Phase, overalls)
• Frequency markers
• Signal post processing for time waveform (overalls)
• ISO standards for evaluation
Valuable additional benefits
• Saving reports on USB pen drive
• Robust carrying case
• Comprehensive accessories
Hardware
• Two synchronous measurement channels for balancing in two
planes.
• Unlimited storage capacity (Standard: 2 GB CompactFlash).
• Dustproof and splashproof (IP65) - ideal for use in demanding industrial environments
• Connector for NiCrNi thermocouples
• Stroboscope control output
VIB 5.310 B VIBXPERT II 'Balancer' package :
VIB5.310 VIBXPERT II FFT data collector, incl. battery (VIB 5.325)
VIB 5.317-B Firmware-Zertifikat ‚Balancer‘
VIB 5.320-INT Charger
VIB5.328 Case
VIB 5.330 MEM Connecting adapter for USB pen drive
VIB 5.330-USB USB pen drive
VIB 5.330 SUSB USB cable for communication
VIB5.356 Carrying pouch
VIB 3.306 Reflective tape, 10 mm
VIB 3.420 Magnetic holder for curved surfaces, 2x
VIB 4.750 Extension (5 m) for trigger cable VIB 5.432-2,9
VIB 5.339 Extension (8 m) for Linedrive sensor cable
VIB 5.432-2,9 Cable for Trigger / RPM sensor
VIB 5.436 Linedrive sensor cable, spiralized
VIB 5.437-2,9 Linedrive sensor cable, straight
VIB 6.147 Mobile accelerometer for low-speed machines, 2x
VIB 6.631 Laser trigger sensor
VIB 6.632 Trigger stand
LIT 53.203.EN VIBXPERT II Balancer, operating instructions
LIT 53.103.EN VIBXPERT II Balancer, short instructions
LIT 01.800 CD ROM, Condition Monitoring catalogues, brochures, magazines
VIB8.970 CD ROM, Condition Monitoring Software & Firmware
Balancer is a portable hardware monitoring device that
supports four-channel vibration data collection, analysis,
and balancing. Use the device to collect data from sensors on
a route, for machine-side analysis and diagnosis, and on-site
dynamic balance correction.
The SCOUT140EX is ATEX Zone 2 and IECEx Zone 2 compliant
and safe for hazardous areas. It is both light and rugged. The
neck strap includes an integrated Sensor Keeper that
restrains your sensor while you walk or climb to reach other
machines.
The device includes a complete suite of advanced recording
and analysis capabilities, including tri-axial and 6Pack
recordings, coast-down, long time waveform, modal analysis
and cross channel spectrum (ODS).
The SCOUT140EX offers plenty of storage and long battery life.
The device comes with a five year warranty. It works with
System 1 software.
The SCOUT140EX Vibration Data Collector, Analyzer and
Balancer offers the following features:
l Up to four-channel, simultaneous on-route recordings
l Simultaneous acquisition, two-plane balancing with up
to four sensors
l Unique 6Pack recording system
l DC-coupled sensor support
l Support for acceleration, velocity, displacement, DCcoupled, current and voltage output sensors
l Triax-enabled
l One GB memory plus virtually unlimited spectra and
waveform storage
SCOUT140-Ex comes with a full suite of advanced recording and
analysis capabilities including tri-axial and 6Pack recordings,
coast-down, long time waveform, modal analysis and cross
channel spectrum (ODS).
SCOUT140-Ex offers plenty of storage and long battery life. The
device is backed by five years of warranty.
SCOUT140-Ex is one of Bently Nevada hardware monitoring
assets that work with System 1* as well as Ascent* Level 2
software.
Safe, simple, precise
The new VibScanner 2 Ex is a next-generation, explosion protection system for quickly detecting machine vibration in hazardous work environments. Measuring simultaneously on three axes, the VibScanner 2 Ex sets the benchmark for fast and accurate measurements of machine, gear, and bearing issues.
This is the ultimate tool for fast and accurate machine vibration measurements. The VibScanner 2 Ex heightens efficiency and data quality. In just a quarter of the time of a standard data-collector, it precisely measures available data in three axes. Equipped with a triaxial sensor, it requires only one measurement point and the click of a button to begin collecting machine data.
This device is ideal for route-based maintenance jobs in environments where explosion protection standards are required. Its rugged magnetic foot of the triaxial sensor fits perfectly on the housing of any motor, pump, fan, or other rotating device, detecting vibration right near the source.
The "Triax-Effect"
The VibScanner 2 Ex will diminish worries about finding the right measurement points at the machine. Because it features a Prüftechnik triaxial sensor, just one measurement point is required instead of three separate ones. This saves considerable time without sacrificing data quality. The “Triax-Effect” enables users to obtain measurements up to four times faster than the industry standard while achieving new levels of data quality.
ones. VibScanner 2 Ex thus saves considerable time without sacrificing data quality. The “Triax-Effect” enables obtaining measurements up to four times faster than the industry standard while achieving new levels of data quality.
Speed—the root cause of all fault patterns
A unique speedfinder tool is an exclusive feature of the VibScanner 2 Ex. This tool directly evaluates the exact rotational speed of any machine from the raw measurement data. Rotational speed is crucial to determining fault patterns, particularly when operating on assets with variable rotational speeds. With the speedfinder tool, no additional measurements are necessary. Time is saved on-site, and the vibration analysis specialist has the exact machine speed available in their analysis.
Specifically designed for route-based maintenance jobs in hazardous areas
Fast and comprehensive data collection
No training is required, thanks to an intuitive graphical user interface
Minimal time spent at machine, due to parallel digital data processing
Real triaxial data acquisition
RPM Finder generates swift RPM determination based on signal
Touch display: shock-proof, high-contrast, glove-enabled
General specifications
Measurement
Channels
Number 3 synchronous analog channels (X/Y/Z)
Z channel
(0 ... 50 kHz)
-20 .. 20 V, input impedance: 78 kOhm
IEPE
Current Linedrive
X/Y channel
(0 ... 10 kHz)
-20 .. 20 V, input impedance: 78 kOhm
IEPE
Dynamic
range
109.5 dB (total)
Sampling rate up to 131 kHz per channel
Signal
processing
3 x 24 bit ADCs
Measuring
range/Accuracy
Vibration acceleration: dependent on used sensor
Shock pulse: -10 dBsv to 80 dBsv /- 2 dBsv
Fulfilled
standard
DIN ISO 2954:2012 (2-1 kHz, 10 Hz -1 kHz, 10-10 KHz)
Display Type Capacitive touchscreen
Optically bonded for high contrast and increased shock
resistance
Active area 95 x 54 mm (3 3/4” x 2 1/8”)
Size 10.9 cm (4 1/3“)
Color depth 16 million colors
Viewing
angle
< 140°
Operation Multi touch – gesture control
Glove-compatible
Illumination Background lighting, adjustable
Ambient light
sensor
Yes
Supply Type Li ion rechargeable battery
Nominal
voltage
7.3V
Energy density 50 Wh
Charge time,
typical
3.5 h (0 ... 100 % @ 25 °C / 77 °F)
2.5 h (0 ... 80 % @ 25 °C / 77 °F)
Charging
temperature
10 °C ... 40 °C
[ 50 °F ... 104 °F]
Operating
time, typical
10 h (cont. operation, rech. battery 100 %)
5 h (cont. operation, rech. battery 50 %)
Power adapter 100-240 V~, 50-60 Hz (input)
12 V 3 A (output)
Energy saving
mode
Yes
Computer Processor ARM A9 - Quadcore 1 GHz
Operating
elements
Touchscreen, ON/OFF key, Enter key
Memory microSD card, 32 GB for measurement data, permanently
installed
2 GB RAM
USB 1 x USB 2.0, device interface
RFID RFID reader module for PRÜFTECHNIK transponder:
ALI 50.628 EX0-25
Complies with ISO 14443a and ISO 15693
Reading distance: 2...3 cm (13/16” ... 1 3/16”)
WiFi IEEE 802.11a/b/g/n/ac
Throughput: < 200 Mbps
Security: WPA2
Stroboscope Frequency range: 0.1 – 1000 Hz
Resolution: 0.06 1/min.
LEDs: Risk group 1 per IEC 62471
LED 1x RGB LED (display for battery status and charging
process)
General specifications
Environment
/ mechanical
system
Connections Socket for power adapter
Micro USB for data cable
Plug-in connector (8-pole) for signal cable
Housing, EX
device
Housing: PC
Sheath: TPE, black, antistatic, conductive
Dimensions 203 x 143 x 76mm (LxWxH) (8 x 5 5/8 x 3”)
Weight approx. 1.0 kg (35.3 oz)
Degree of
protection
IP55
Temperature
range
Operation: 0°C ... 50°C [ 32 °F ...122 °F ]
Storage: -20 °C ... 60 °C [-4 °F ... 140 °F ]
Air humidity 0 ... 90 %, non-condensing
Certifications CE, RoHS, FCC, FCC/IC, ATEX, IECEx,
NEC 500/505, CEC Annex J18, CEC sect. 18
General specifications
Ex-Data
CSA – only
for U.S. and
Canada
CSA certificate
number:
CSA20CA80035102X
Install per control
drawing:
LIT 52.300.EN
Marking of the
device:
Ex ec [ic] IIC T4 Gc
Ex tc [ic] IIIB T135°C Dc
Class I, Zone 2, AEx ec [ic] IIC T4 Gc
Zone 22, AEx tc [ic] IIIB T135°C Dc
Class I, Div. 2, Groups A, B, C, D T4
Class II, Div. 2, Groups F, G, T4, Class III, Div.2
Associated equipment for Class I, Division 2,
Groups A, B, C, D
Associated equipment for Class II, Division 2,
Groups F, G
Associated equipment for Class III, Division 2
Ex-Data
ATEX, IECEx
ATEX certificate
number:
EPS 19 ATEX 1 119 X
IECEx certificate
number:
IECEx EPS 19.0057X
Marking of the
device: II 3G Ex ec [ic] IIC T4 Gc
II 3D Ex tc [ic] IIIB T135°C Dc
A unique handheld measuring device with which even untrained personnel can easily and effectively measure machine vibration on rotating machinery. Thanks to its forward-looking measuring principle and data acquisition across three axes with the triaxial sensor, all relevant condition information is recorded with the touch of a single button. And at a measurement speed that opens up fully new dimensions. Not only is the VIBSCANNER 2 a breakthrough in terms of measurement speed and precision, but also through its robustness and its intuitive operating concept.
The intuitive graphical user interface assists the employee en route in taking repeatable error-free measurements. The device provides him/her with the exact information about the status of the measurement locations and the progress of the route.
Following completion of the measurement route, the data pack containing the results can be downloaded onto the PC and sent to the maintenance specialist by email. This means that the maintenance specialist is always provided with high-quality vibration and machine condition data which he can analyze with the OMNITREND Center software.
The bottom line: High-speed vibration measurement without any loss of data or quality while both the employee on site and the maintenance specialist save a great deal of time.
Collecting and analyzing machine data efficiently
Fast and comprehensive data collection
Minimum training required thanks to intuitive graphical user interface
Minimum time at machine thanks to parallel digital data processing
Real triaxial data acquisition
RPM Finder: innovative RPM determination based on signal
Touch display: shock-proof, high-contrast, glove-enabled
Technology
VIBSCANNER 2 is the high-speed vibration data collector of the next generation.
Depending on the filter settings, it measures overall values, spectra, and time signals synchronously in 3 axes. In combination with a triaxial sensor, VIBSCANNER 2 collects even more machine condition data per measurement location.
Added value thanks to additional vibration data without affecting the measurement time
Quick data acquisition thanks to synchronous measurement in 3 axes
Clear channel assignment without any additional cable adapter
A triaxial sensor measures vibration in 3 perpendicular directions at once, while a single-axis sensoronly measures in one direction at a time. Certain conditions such as cocked bearing or a bent shaft can be identified in a single measurement with a triaxial sensor.
The bottom line: In combination with a triaxial sensor, VIBSCANNER 2 delivers even more comprehensive information per measurement location at the push of a button. This creates an overall image of the machine‘s health without affecting the measuring time.
VIBSCANNER 2 – Technical data
Parameter VIBSCANNER 2
Measurement channels
Number 3 synchronous analog channels (X/Y/Z)
Z channel (0 ... 50 kHz) -20 .. 20 V, input impedance: 78 kOhm
IEPE
Linedrive
X/Y channel (0 ... 10 kHz) -20 .. 20 V, input impedance: 78 kOhm
IEPE
Dynamic range 109.5 dB (total)
Sampling rate up to 131 kHz per channel
Signal processing 3 x 24 bit ADCs
Measuring range / Accuracy Vibration acceleration: dependent on used sensor
Shock pulse: -10 dBsv to 80 dBsv /- 2 dBsv
Fulfilled standard DIN ISO 2954:2012 (2-1 kHz, 10 Hz -1 kHz, 10-10 KHz)
Display
Type Capacitive touchscreen
Optically bonded for high contrast and increased shock resistance
Active area 95 x 54 mm [3 3/4” x 2 1/8”]
Size 10.9 cm [4 1/3“]
Color depth 16 million colors
Viewing angle < 140°
Operation Multi touch – gesture control
Glove-compatible
Illumination Background lighting, adjustable
Ambient light sensor Yes
Supply
Type Li ion rechargeable battery
Rated voltage 7.2 V
Energy density 72 Wh
Charge time, typical 5.0 h (0 ... 100 % @ 25 °C / 77 °F)
3.5 h (0 ... 80 % @ 25 °C / 77 °F)
Charging temperature 10 °C ... 40 °C
[ 50 °F ... 104 °F]
Operating time, typical 12 h (continuous operation, rechargeable battery 100 %)
6 h (continuous operation, rechargeable battery 50 %)
Power adapter 100-240 V~, 50-60 Hz (input)
12 V 3 A (output)
Energy saving mode Yes
Computer
Processor ARM A9 - Quadcore 1 GHz
Operating elements Touchscreen, ON/OFF key, Enter key
Memory microSD card, 32 GB for measurement data, permanently installed
2 GB RAM
USB 1 x USB 2.0, device interface
RFID RFID reader module for PRÜFTECHNIK transponder ALI 50.628-25
Complies with ISO 14443a and ISO 15693
Reading distance: 2...3 cm (13/16” ... 1 3/16”)
WiFi IEEE 802.11a/b/g/n/ac
Throughput: < 200 Mbps
Security: WPA2
Stroboscope Frequency range: 0.1 – 1000 Hz
Resolution: 0.06 1/min.
LEDs: Risk group 1 per IEC 62471
LED 1x RGB LED (display for battery status and charging process)
Environment / Mechanical system
Connections Socket for power adapter
Micro USB for data cable
Plug-in connector (8-pole) for signal cable
Housing 2-component housing: PC and ABS
Sheath: TPE, black
Dimensions 203 x 143 x 76mm (LxWxH) [8 x 5 5/8 x 3"]
Weight approx. 1.0 kg [35.3 oz]
Degree of protection IP65, dust-proof and spray water-protected
Temperature range Operation: -10 °C ... 50 °C [ 14 °F ...122°F ]
Storage: -20 °C ... 60 °C [-4 °F ... 140°F ]
Air humidity 0 ... 90 %, non-condensing
Certifications CE, RoHS, FCC, FCC/IC
The SCOUT100-EX is ATEX Zone 2 and IECEx Zone 2 compliantand safe for hazardous areas. It is both light and rugged. Theneck strap includes an integrated Sensor Keeper that restrainsyour sensor while you walk or climb to reach other machines.
The device includes a complete suite of advanced recordingand analysis capabilities, including 6Pack recordings, coast-down and long time waveform.The SCOUT100-EX offers plenty of storage and long batterylife. The device comes with a five year warranty. It works withSystem 1 software.
The SCOUT100EX Vibration Data Collector, Analyzer and Balancer offers the following features:
- Up to two-channel, simultaneous on-route recordings
- Unique 6Pack recording system
- DC-coupled sensor support
- One GB memory plus virtually unlimited spectra and waveform storage
- Ten hours of battery life
- 6,400 lines FFT resolution
- 40 kHz Fmax
- Wide measurement range — 1,000 g, 25,000mm/s, 2,500mm
- Two-plane balancing Laser speed sensor for automatic capture of machine running speed
- Keyphasor tach mode
- Dynamic range ≥ 95 dB
- USB host port for data transfer to external USB memory
- Excellent ergonomics for walk-around data collection
- High contrast, backlit and direct-sunlightr eadable LCD
- True left and right-handed operation
- Sensor cable self-test feature
- Lightweight, rugged IP65 rated case
- Five-year warranty on the instrumenthardware
- ATEX and IECEx Zone 2 hazardous location certification
- Field-upgradable Proflash system and free firmware updates for five years
Specifications
Sensors
Sensor input
Two Channels Simultaneous sampling
Compatible sensor types
Accelerometer, velocity,displacement, current
AC coupled range
16 V peak-peak
Allows for ± 8 V sensor output
swing (± 80 g)
DC coupled ranges
0 to 20 V
-10 to 10 V
-20 to 0 V
E.g. for reading prox-probe gap
Connectors
Safety feature: Break-free inline connector
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA (configurable),
24 V maximum
2.2 mA required power for
IEPE/ICP-type accelerometer
Sensor detection
Warns if short circuit or not connected
Waveform Display
Number of samples
1024, 2048, 4096, 8192, 16,384
Time scale
10 ms to 256 seconds or orders based from 1 to 999 revs
Time synchronous averages
1, 2, 4, 8, 16, 32, 64, 128
Only available when tachometer is triggered
Long time waveform
25 Hz to 40 kHz
Fmax
20 kHz dual channel
Long time waveform duration
14.7 million samples (total over channels)
E.g. for Fmax 1 kHz
Fsample = 2.56 kHz and
Duration = 1.6 hrs
Tachometer
Sensor
Laser sensor with reflective tape Sensor triggers on beam reflection
Laser sensor range
10 cm to 2 m nominal
Range depends on size of reflective tape
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Instrument has optically isolated input
Power supply to sensor
5 V, 50 mA
TTL pulse rating
3.5 V (4 mA) min
28 V (5 mA) max Off-state 0.8 V
Keyphasor threshold
7.7 ± 0.5 V , 13.2 ± 0.8 V , 18.5 ± 1 V , Nominally 8 V, 13 V, 18 V
Speed range
10 RPM to 300,000 RPM (0.2 Hz to 5 kHz)
Pulse width at least 0.1 ms
Accuracy
± 0.1 %
Output to drive strobe
Up to 140 Hz (8400 CPM) Typical Depends on strobe type Special cable required
Logging and Analysis
Output formats
LCD screen, Ascent, XML, System 1
Data storage
Dual 1 GB non-volatile flash memories, Database mirror copy on second flash memory
Data storage structure
Folders/machines/points/locations/routes
No limits are applied 50 character names
Max folder size
10,000 measurement locations
Parameter Indication
Maximum levels (peak)
> 1000 g (10,000 m/s2)
> 1000 in/sec (25,000 mm/s)
> 20 in (500 mm)
> 10,000 Amps
Effective limit is sensor sensitivity
and output voltage
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical Other distortions and noise are lower
Units
g or m/s2 or adB, in/s or mm/s or vdB, mil or mm or µm amps
0-peak, peak-peak or RMS, Auto-scale by 1000x when required US and SI options for adB and vdB
Magnitude & cursors
Overall RMS value Waveform True pk-pk , Dual cursors Harmonics, Digital readouts on chart
Base accuracy
± 1% of readings
approximately 0.1 dB
For DC level — % of full scale
For AC signal — % of reading
High frequency attenuation
≤ 0.1 dB >100 Hz to 10 kHz
≤ 3 dB >10 kHz to 40 kHz
Attenuation tolerances are in addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to <100 Hz
≤ 3 dB 1 Hz to <10 Hz
Attenuation
due to
Integration
≤ 0.1 dB 1 Hz to <100 Hz
≤ 1.5 dB 0.2 Hz to <1 Hz
≤ 0.1 dB 10 Hz to <100 Hz
≤ 1.5 dB 1 Hz to <10 Hz
Low frequency mode:
When Coupling = DC and Fmax
≤ 100 Hz
Normal mode is applicable in all other cases. Values apply to single integration.
(Acceleration to velocity) Double the values for double integration (Acceleration to displacement)
Balancing
Planes
Up to 2 planes, 2 sensors
Speed range
30 to 60,000 RPM
Measurement type
Acceleration, velocity, displacement
Weight modes
Angle 0° to 360°, fixed position,
circumference arc
E.g. weights on fan blades, linear distance around circumference
Remove trial weights
Yes/No Automatic recalculation
Manual data entry
Yes Allows re-entry of previous balance jobs
Storage
Against machines in data structure,No limits applied
Mechanical
Size 9.9" W x 5.8" L x 2.4" H (252 x 148 x 60 mm)
Weight 2.7 lb (1.2 kg)
Including battery and strap
Spectrum Display
Fmax ranges
25, 50, 100, 125, 150, 200, 300,400, 500, 600, 800, 1000, 1200,
1600, 2000, 2500, 3000, 4000, 5000, 6000, 8000, 10,000,15,000, 20,000, 30,000, 40,000 Hz
Or equivalent CPM values, Or orders-based from 1X to 999X
Fmin possible range
0 to Fmax
Instrument zeroes all spectral lines below Fmin.
Resolution
400, 800, 1600, 3200, 6400
lines. 3200 lines max. for dual channel measurements
Frequency scale
Hz, CPM, Orders, Linear scale with zooming
Amplitude scale
Acceleration, velocity, displacement or current
Linear or log scales, auto or manual scaling
Window shapes
Hanning Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75, 87.5) %
Depends on Fmax and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time proportionally
Averaging types
Linear, exponential, peak hold, synchronous
Demodulation bandwidths
23 bandwidth options
From 125 Hz to 1250 Hz Up to 16 kHz to 20 kHz
6Pack
Up to 40 kHz & 3200 lines (1 channel)
Up to 20 kHz & 1600 lines (2 channels)
Spectrum and waveform for low-frequency,high-frequency demodulation
Order tracking
Up to 6 kHz Fmax, orders based Tachometer required Mounted on high-speed shaft
Order tracking - Distortion
Less than -65 dB
Within 50% to 200% speed variation during recording
Display and Communication
Display
Graphic Grayscale LCD , White LED Backlight
Resolution & size
480 x 320 (HVGA), 5.5” (140 mm) Readable in direct sunlight
Supported Languages
English, French, Spanish, Portuguese, Russian, Chinese
Communication with PC
US and Ethernet (optional USB dongle), Use PROFLASH to upgrade instrument firmware
USB host port
USB 2.0, supplying 5V, 250mA, Save folders to USB flash drive
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V, 5000 mAh
Operating time
10 hours Backlight on — 60 second timeout
Charger type
Internal charging, automatic control, External power pack 12 V DC, 3 A output
Charge rate
3 A nominal
3 hours for complete charge
Environmental Limits
Operating temperature
14 °F to 122 °F (-10 to 50 °C)
Storage temperature & humidity
-4 °F to 140 °F (-20 to 60 °C), 95% RH, Up to 95 F (35 C), 85% RH if
storage exceeds one month
Ruggedness
4’ (1.2 m) drop onto concrete,IP65
Procedure: 26 drops following
MIL-STD-810F-516.5-IV
Also you can check product : Bently Nevada SCOUT100-Ex Vibration Analyzer , Data Collector, Balancer - NEW
Input
Analog, Vibration, 2x : Voltage (AC/DC, ±30 V max.)
Current (AC/DC, ±30 mA max.)
IEPE-type accelerometer (2 mA, 24 V max.)
Current Linedrive (CLD) accelerometer (10 V, 10 mA max.)
Frequency range : DC ... 51.2 kHz (Acceleration from 0.5 Hz)
Dynamic range : 96 dB (measurement) / 136 dB (total)
Sampling frequency : up to 131 kHz per channel
Impedance : 90 kOhm, with cable VIB 5.433
Analog, Temperature, 1x : Thermocouple (type K)
Digital, Pulse/ Tacho, 1x : RPM, Trigger, Keyphaser with pulse and AC signals: 0 V ... 26 V or -26 V ... 0 V
Max. input voltage : ± 26 V
Switching threshold for 0 V ... 26 V signal : max. 2.5 V rising, min. 0.6 V falling
Switching threshold for -26 V ...0 V signal : min. -8 V rising, max. -10 V falling
Pulse width : < 0.1 ms
Output
Stroboscope control : TTL
Frequency range : 0 - 500 Hz
Resolution : 0.05 Hz
Signal-Out : Connection for headphones to listen to the analog input signal; signal processing (oscilloscope)
Frequency range : 0.5 Hz - 40 kHz
Output impedance : 100 Ohm
Measurement range / Accuracy
Vibration acceleration : depends on the sensor connected
Shock pulse : -10 ...80 dBsv / ± 3dBsv
RPM : 10 ... 200 000 min-1 / ±0.1‰ or ± 1 min-1 (the lower accuracy is applicable)
Temperature, type K : -50 ... 1000°C / 1% or ±1°C (the lower accuracy is applicable)
Standards fulfilled : Frequency response acc to ISO 2954
Display
Type : TFT-LCD, backlit
Pixel area : 116 x 87 mm
Resolution : VGA (640 x 480 pixel) with 140 ppi
Color depth : 18 bit (262144 colors)
Power supply
Battery type : Li Ion rechargeable battery pack (7.2V / 4.8Ah - 34 Wh)
Charging time : < 5 hours in the instrument
Charger, input : 110-240 V / 50-60 Hz
Charging temperature : 0°C ... 50°C [ 32 °F ... 122°F]
Computer
Processor : Marvell PXA320 806 MHz
Keyboard : 1 navigation pad and 7 keys (Zoom, Escape, Function, Help, Menu, On/Off); Keyboard illumination controlled by ambient light.
Memory : Internal: 128 MB DDR RAM; Compact Flash: 2 GB to 8 GB (interchangeable)
Serial interface : RS 232, <115 kBaud USB interface USB 2.0
Ethernet interface : 100 Mbit (100Base T), 10 Mbit (10Base T)
Environment / General
Connectors : Analog / Digital channels: MiniSnap socket Thermocouple (type K): QLA socket; all compatible to VIBSCANNER
Housing : ABS plastics
Dimensions : 186 x 162 x 52 mm (LxWxH), [ 7 5/16" x 6 3/8" x 2 1/16" ]
Weight : approx. 1.1 kg [39 oz]
Environmental protection : IP65, dust and splash-proofed
Temperature range : -10°C ... 60°C (Operation), [ 14 °F ... 140°F]
-20°C ... 60°C (Storage), [ -4 °F ... 140°F]
INCLUDED :
- VIBXPERT II
- 2 Channels
- 2x Accelerometers with magnets
- Accelerometer for balancing
- Machine template module
- Channel balancing module
- 2x Regular sensors and low rpm sensor
- 2x Vibcode transducers
- Optical pickup
- Laser rpm
- Tiptector
- PC Transfer cable
- Accelerometer cable
- Power supply
- With inplace balancing module and laser
- Vibration sensor
In The Box
A4300 VA3 Vibration Meter
Charger
Leather holster
Carrying strap
Hard shell Profi Case
One standard sensor
One 6ft. coiled cable
Flat rare earth magnet
Order additional software modules, cables and accessories as needed
Machinery condition monitoring is a necessity also in hazardous industry environments such as mines, oil & gas, petrochemical etc. To protect human lives and equipment the devices used in such harsh areas has to be explosion proof. VA3 Pro Ex is ready at your service.
VERSATILITY & CONNECTIVITY
VA3 Pro Ex
3x AC input – vibrations
3x DC input – process values
1x Trigger input (speed probe)
Triaxial sensor readyIR temperature sensor
LED stroboscope / flashlight
Fast USB 2.0 communication
Robust Push-Pull connectors
Collect & Import
VA3 Pro Ex along with free DDS software can measure and store two basic measurements. Acceleration in g for the bearing condition and Velocity in mm/s (or ips) for the whole machine body condition.
Collect the data with VA3 Pro Ex regularly and import them into free DDS software. Follow vibration trends and observe the actual condition of your machines.
The mobile solution for machinery health monitoring
The VibXpert 3 Balancer is an advanced smart condition monitoring field balancing tool that enables users to quickly and effectively correct unbalance faults.
With the VibXpert 3 Balancer, users can:
- Increase the reliability of their machinery by reducing excessive machine vibration levels
- Improve safety by reducing potential equipment hazards
- Improve uptime by promptly identifying and correcting unbalance
- Help meet industry standards and regulatory compliance requirements
- Improve energy efficiency of rotating machinery, providing cost savings
- Maximize the efficiency, quality, and accuracy of field balancing jobs
The result is extended peak operating asset performance, more effective resource use, and increased business value from operations.
The next-generation in field balancing
One and two plane field balancing
Well balanced machines have reduced risk of resonance vibration
- Intuitive and interactive interface
Simplified, easy-to-use touch screen user interface
6 channel measurement and modern data processing
- Better balancing results
- Optimized calculations – simultaneously minimize vibration levels across all machine points
- Complete insights on overall vibration levels and FFT data during balancing
Comprehensive balancing reports
- Balancing reports include overall vibration levels, spectral graphs, polar plots, and much more
Fast, accurate, advanced balancing device
- Best practice and customizable machine templates
- Modern data processing: 6 synchronous analog channels
- Enhanced balancing reports
- Simplified data management and analysis
- Captures balancing data, overall vibration values, and spectral data
- Large, user-friendly touchscreen
- Dual-redundant button configuration
- IP-65 rated, shockproof, scratch resistant and drop proof
Technology
The next-generation field balancing solution.
Unbalance, resulting from uneven mass distribution around a rotational axis is the leading cause of unplanned downtime and costly damage.
Today, machines operate at variable speeds, sometimes near their engineered capacity, increasing the risk of resonant vibration. Balanced machines mitigate this risk. The VibXpert 3 Balancer offers a highly efficient and user-centric experience, faster balancing results with better insights, and enhanced fault detection on rotating assets.
Machine templates
It boasts an interactive user interface with preconfigured and customizable machine templates, reducing the complexity of the balancing process.
Modern data processing
Its modern data processing capability, optimized software-based calculations from raw sensor data offers faster measurements, complete insights during balancing (including overall vibration levels, FFT spectra, phase, and time waveform).
6-channel measurements
VibXpert 3 Balancer enhances fault detection through synchronous 6-channel measurement, enabling users to minimize overall vibration levels simultaneously across all machine measurement points
Enhanced balancing reports
Balancing reports encompassing all necessary information for users, including overall vibration levels, spectral graphs, polar plots, and machinery details, among others.
Also you can check : Sale Trimble SX12 [Imaging and 3D] Scanning Total Station - NEW
Features:
All basic vibrodiagnostics measurements: Overall values, Time signal, Frequency bands, FFT Spectrum, Route measurement
4 MB memory for data storage
detects unbalance, loosenes, misalignment or bearing faults
ISO 10816-3 included
8 hours of operation
determines the condition of your bearings, including slow-running ones
SPECS :
Input: 1 x ICP® powered Ex accelerometer (AC90x or AC91x)
Input range: 60 g PEAK with standard 100 mV/g sensor
Measurements: Velocity RMS: 10 - 1 000 Hz [mm/s, ips]
Velocity PEAK: 10 - 1 000 Hz [mm/s, ips]
Acceleration RMS: 500 - 16 000 Hz [g]
Acceleration Peak: 500 - 16 000 Hz [g]
Velocity time: 1 - 1 000 Hz [mm/s, ips], 2048 samples *
Velocity spectrum: 1 - 1 000 Hz [mm/s, ips], 800 lines
Acceleration time: 1 - 16 000 Hz [g], 2048 samples*
Acceleration spectrum: 1 - 16 000 Hz [g], 800 lines*
Acceleration Demod-Envelope RMS: 500 - 16 000 Hz [g]
Acceleration Demod-Envelope Peak: 500 - 16 000 Hz [g]*
Acceleration Demod-Envelope time: 500 - 16 000 Hz [g], 2048 samples
Acceleration Demod-Envelope spectrum: 500 - 16 000 Hz [g], 800 lines,
range 400 Hz*
Displacement RMS: 2 - 100 Hz [µm, mil]
Displacement 0-Peak: 2 - 100 Hz [µm, mil]
Displacement Peak-Peak: 2 - 100 Hz [µm, mil]
Other functions: Vibration stethoscope
Memory: 4 MB for data
900 measurements of 800 line spectra or 2048 sample time signals
may be stored
Data storing: Off-Route
Route with DDS software for Vibrio M Ex (free download)
Interface: USB 2.0 compatible
Software: DDS software for Vibrio M Ex (free download)
Display: Colour graphic OLED display 128x128 pixels, diagonal 1.5“ (38 mm)
Output: 1 x AC signal 8 Ω / 0,5 W for external headphones (signal listening)
Power: 2 x AA 1.5V batteries (Energizer L91 Ultimate Lithium - 7 hours operation)
Temperature: Operating: -20°C to 50°C
Dimensions: 150 x 60 x 35 mm
Weight: 330 g including batteries (without cable, sensor and magnet)
540 g including batteries, cable, sensor and magnet
Accessories: Ex vibration sensor (AC90x or AC91x), coiled cable to connect vibration
sensor, magnetic base for vibration sensor, headphones with 3.5 mm
jack, special USB cable, measuring tip for manual pressure on the sensor,
transport case, USB flash disc with the manual
II 2 G Ex ib IIC T4 Gb: II Non-mining
2 Zone 1
G Gas atmosphere
Ex ib Principle of protection:
Intrinsic Safety EN 60079-11 , Zone 1
IIC Gas group - Acetylene, Hydrogen
T4 Temperature class 135°C
Gb Equipment Protection Level – Zone 1
(high protection)
What's in the Box:
(1) Ex vibration sensor (AC90x or AC91x)
(1) Coiled cable to connect vibration sensor
(1) Magnetic base for vibration sensor
(1) Headphones with 3.5 mm jack
(1) USB cable
(1) Measuring tip for manual pressure on the sensor
(1) Transport case
(1) USB flash disc with the manual
(2) AA 1.5V batteries
Also you can check price : Adash VIBRIO M A4900 Vibration Analyzer and Data Collector in One - NEW
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.
The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.
- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200
Hardware Features:
- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.
Software Features
- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.
Data Collector Specifications
Sensors
Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.
Compatible sensor types
Accelerometer, velocity,
displacement, and voltage.
AC coupled range
16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).
DC coupled ranges
0 to 20 V, -10 to 10 V, -20 to 0 V
Connectors
2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors
Sensor detection
Measures sensor bias
voltage.
Warns if short circuit or not
connected.
Tachometer
Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.
Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.
Input Impedance & max values
100 KΩ
± 28 V max
Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy
Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable
Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)
Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)
Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).
Parameter Indication
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.
Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS
Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart
Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)
High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz
Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).
Spectrum Display
Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.
Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.
Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200
Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.
Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.
Window shapes
Hanning, Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally
Averaging types
Linear, exponential, peak hold
Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz
6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation
Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768
Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs
Balancing
Planes 2 planes, 2 sensors
Speed Range 3 to 12,000 RPM
Measurement Type
Acceleration, Velocity,
Displacement
Weight modes
Angle 0° to 360°
Fixed Positions
Remove Trial Weights
Yes/No
Automatic recalculation
Storage
Balance jobs stored on
handheld and transferable
to System 1
Communication
Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.
Operating Time
10 hours typical on-route data
collection
Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.
Charge rate
2 A nominal 3 hours for complete charge.
Mechanical
Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )
Weight 1.5 lb ≈ 680g
Environmental Limits
Operating temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas
Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)
Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.
Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65
S1 Collector App
Operating System
Android 5.1 to 12
Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish
Also you can check : Adash VIBRIO M Ex A4900 Vibration Analyzer and Data Collector - NEW
Our innovative SCOUT200 series is a smart, intrinsically safe, and highly portable data collector that is fully supported by the System 1 condition monitoring and diagnostic software. The data collector works in tandem with the System 1 Collector app, running on an industrial smartphone or tablet. Users can collect & analyze vibration data, take photos, send text messages, check email, make phone calls, and run other enterprise applications.
Bently Nevada’s SCOUT200 series is comprised of easy to use, small form-factor portable vibration data collectors. The SCOUT220-IS (2 channel) and SCOUT240-IS (4 channel) is Intrinsically Safe (IS) hazardous-rated portable data collector designed for ATEX Zone 1 and CSA Class 1 Zone 1 hazardous areas.
The SCOUT200 series represents the next generation of smarter, intrinsically safe portable data collectors from Bently Nevada.
- Modern - de-couples data acquisition and display, uses rugged industrial Android handhelds
- Flexible - choose compact 5"" screen for data collection, or large 8"" tablet for analysis
- Connected - WiFi, Bluetooth, Cellular, Internet, other apps...
- Intrinsically Safe - Full IS-rated SCOUT200, with same full performance as non-rated COMMTEST200
Hardware Features:
- Battery life of 10 hours allows the data collector to run all day.
- Five year warranty.
- Rugged, water, and dust resistant (IP-65), drop-tested, with intrinsically safe
variants.
- Easy to carry: lightweight handheld unit, shoulder strap for data collector, keepers for sensors.
- Safety breakaways on both shoulder strap and sensor cables.
- Upgradable industrial handheld smartphone or tablet.
- Handheld Push-to-Talk(PTT) button is configured to start measurements
(where available).
- Up to four channel simultaneous recordings (including on-route).
- SCOUT240 supports Triaxial sensors.
- Up to 12,800 lines of spectral resolution, 80 kHz Fmax.
- Supports accelerometer, velocity, displacement, and voltage-output
sensors of AC and DC coupling types.
Software Features
- Seamless on-and off-route data collection.
- Route overview & easy route navigation.
- Fast sensor settling and data collection.
- Patented 6Pack time-saving measurement type.
- Synchronous sampling, peak demod, and bump test.
- Coast-down, run-up, and interval capture support.
- Custom note and numeric data entry.
- Rotor Balancing, dual plane, reports transferred to System 1.
- Data quality warnings and easy-tounderstand alarm annunciation.
- Supports operator driven reliability (ODR).
- Cross Channel Phase measurement & reports.
Data Collector Specifications
Sensors
Sensor input Simultaneous sampling
SCOUT220IS : 2 channels.
SCOUT240IS: 4 channels.
Compatible sensor types
Accelerometer, velocity,
displacement, and voltage.
AC coupled range
16 V peak-peak.
Allows for ± 8 V sensor
output swing (± 80 g).
DC coupled ranges
0 to 20 V, -10 to 10 V, -20 to 0 V
Connectors
2 x LEMO connectors for CH1 & CH2
1 X LEMO connector for Tach/Keyphasor
SCOUT240IS includes a CH 2.4 breakout cable.
Analog to digital conversion
24-bit ADC
Sensor excitation current
0 mA or 2.2 mA
(configurable), 24 V
maximum
2.2 mA powers IEPE/ICP-type
sensors
Sensor detection
Measures sensor bias
voltage.
Warns if short circuit or not
connected.
Tachometer
Optional IS Zone 0 rated laser Tach
Battery-powered, handheld
laser sensor.
Triggers when beam on
reflective tape range 10 cm to
2 m.
Speed 6 to 250 krpm.
Optional Zone 2 rated laser Tach
Laser sensor powered by
Portable Data Collectors.
Triggers when beam on
reflective tape range 10 cm to
2 m. Speed 6 to 250 krpm.
Other sensor types supported
Contact, TTL Pulse, Keyphasor
Power supply to sensor
5 V, 40 mA
Rated for Zone 2, 22 and
Division 2 only.
Input Impedance & max values
100 KΩ
± 28 V max
Waveform display
± 20 V range
Threshold ± 20 V range ± 0.4 V accuracy
Autothreshold mode
Signal ≥ 3 V pk-pk
Machine speed ≥ 60 rpm (1 Hz)
Settles within < 15 s
Hysteresis 0.2 V to 2.5 V user configurable
Speed range
Minimum: 3 rpm (0.05 Hz)
Maximum: 1,200,000 rpm (20
kHz)
Signal pulse width
10 µs minimum 2% duty cycle
(for auto-threshold)
Accuracy
± (0.1 % 1 cpm) for speeds up
to 5 kHz (300 kcpm).
± (0.3 %) for speeds above 5
kHz (300 kcpm).
Parameter Indication
Dynamic signal range
> 95 dB typical at 400 line resolution
Harmonic distortion
Less than -70 dB typical. Other distortions and noise are lower.
Units
g or m/s2
in/s or mm/s
mil or mm or µm
peak, or peak-peak, or RMS
Magnitude & cursors
Overall value: RMS, derived pk,
derived pk-pk Dual cursors
Digital readouts on chart
Base accuracy
For AC signal: ± 1% of readings
For DC level: ± 1% of full scale
(1% is approximately 0.1 dB)
High frequency attenuation
≤ 0.1 dB > 100 Hz to 10 kHz
≤ 3 dB > 10 kHz to 40 kHz
Attenuation tolerances are in
addition to base accuracy.
AC coupling attenuation
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 3 dB 1 Hz to < 10Hz
Attenuation due to Integration
≤ 0.1 dB 10 Hz to < 100 Hz
≤ 1.5 dB 1 Hz to < 10 Hz.
Values apply to single
integration (acceleration to
velocity). Double the values for
double integration
(acceleration to
displacement).
Spectrum Display
Fmax ranges 25; 50; 100; 125; 150; 200; 300;
400; 500; 600; 800; 1,000;
1,200; 1,600; 2,000; 2,500;
3,000; 4,000; 5,000; 6,000;
8,000; 10,000; 15,000; 20,000;
30,000; 40,000; 60,000;
80,000 Hz or equivalen. CPM
values or orders-based from
1X to 999X.
Fmin possible range
0 to Fmax.
Instrument zeroes all spectral
lines below Fmin.
Resolution (Spectral lines)
400; 800; 1,600; 3,200; 6,400;
12,800 lines
Channels 220
max lines
240
max lines
1 6,400 12,800
2 3,200 6,400
3 or 4 N/A 3,200
Frequency scale
Hz, CPM, Orders.
Linear scale with zooming.
Amplitude scale
Acceleration, velocity,
displacement.
Linear auto scaling.
Window shapes
Hanning, Rectangular
Overlap
(0, 12.5, 25, 37.5, 50, 62.5, 75,
87.5) % Dependent on Fmax
and number of lines
Number of averages
1, 2, 4, 8, 16, 32, 64, 128
Increases sampling time
proportionally
Averaging types
Linear, exponential, peak hold
Demodulation bandwidths
23 bandwidth options from
125 Hz to 1,250 Hz and up to 16
kHz to 20 kHz.
Peak demod: 500Hz-40kHz, 1-
40kHz, 2-40kHz, 5-40kHz
6Pack
Up to 40 kHz & 3,200 lines (1
channel).
Up to 20 kHz & 1,600 lines (2-3
channels).
Spectrum and waveform for
each of low-frequency, highfrequency, demodulation
Waveform Display
Number of samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768
Time scale
10 ms to 256 seconds or orders
based from 1 to 999 revs
Balancing
Planes 2 planes, 2 sensors
Speed Range 3 to 12,000 RPM
Measurement Type
Acceleration, Velocity,
Displacement
Weight modes
Angle 0° to 360°
Fixed Positions
Remove Trial Weights
Yes/No
Automatic recalculation
Storage
Balance jobs stored on
handheld and transferable
to System 1
Communication
Bluetooth BT 4.0 Classic (s/n ≤ 101599)
BT 5.0 BLE (s/n ≥ 101600)
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4 V,
3920 mAh.
Not user accessible but
factory replaceable.
Operating Time
10 hours typical on-route data
collection
Charger type
Internal charging, automatic control.
External power pack 12 V DC, 3 A output.
Charge rate
2 A nominal 3 hours for complete charge.
Mechanical
Size 5.1” W x 5.1” L x 1.4” H
( 130 mm W x 130 mm L x 35 mm H )
Weight 1.5 lb ≈ 680g
Environmental Limits
Operating temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas
Ambient temperature for charging battery
32°F to 77°F (0°C to 25°C)
Storage temperature & humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.
Ruggedness drop & sealing
Drop spec MIL-STD-810F516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65
S1 Collector App
Operating System
Android 5.1 to 12
Languages
Chinese, English, Finnish,
German, Japanese, Russian,
Spanish, Turkish
Also you can check : Bently Nevada SCOUT200-IS Portable Vibration Analyzer and Data Collector - NEW